Issue Logs

Item NumberDate InitiatedDate ResolvedParticipantsDescriptionOptionsResolutionJustification
12024-03-192024-03-21AdrianDamage to Eye-safe Laser ComponentOrdering new laser component and purchase wire connector instead of solderingReceived new laser and perform wire connection without issuesSuccessfully demonstrate eye-safe laser in progress review
22023-12-012024-04-04AdrianLaser system is ineffective1. Develop a simple spraying mechanism as backup.
2. Prioritize laser efficacy tests to allow iteration.
Prioritized laser efficacy testsSuccessfully demonstrate laser effectiveness with visible damage to plants
32024-04-022024-04-04ZihanNo-drip nozzle is unable to attain the responsiveness requirements of the sprayerProcure new nozzleChose regular nozzle with peristaltic pump control, allowing responsive control without drip(Pending for regular nozzle arrival)
42024-03-29N/Amoss, ZAAPPHusky PC module is unable to power upCollaboration between moss and ZAAP for a solution
52024-02-15N/APhil, ParthNeed robust and easy camera-base calibration routine1. cal board + measured extrinsics
2. CAD estimation
N/AN/A
62024-02-01N/APhil, Parthneed introductory forward facing dataset1. find existing,
2. annotate with script
roboflowmodel achieves our P/R thresholds with this basic dataset
72024-03-15N/APhil, Parth, AmaarVisual Servoing / camera-to-laser transformN/AN/AN/A